Special Design Begass Fired Steam Boiler

Special Design Begass Fired Steam Boiler

Ürün Açıklaması
 

Particular Layout Begass Fired Steam Boiler
The DZL series quickly installed coal fired steam boiler is the most superior h2o-fire tube boiler in Chinese market place and international market place,this sequence boiler can be utilized in textile,food and corrugated box manufacturing unit with large effectiveness, little in measurement and extended operating daily life. 

The coal fired steam boiler after enhancement normally takes use of structure of wing variety smoke duct,one particular-way screwed smoke tube,arched tube plate,smoke and gas individual area and a number of other advanced technologies,which has enhanced the h2o circulation speed and basic safety aspect.This series boiler is properly developed,compactly produced up, rapidly mounted,mono layer,so that the civil engineering and investment decision could be saved.With these advancement, the boiler’s doing work lifestyle prolong a lot to be the national power conserving solution.

one-6 T Coal  Fired Steam Boiler usally transported as entiraty portion,Potential a lot more than 8t(like 8 t/h)are transported as up human body and bottom body (chain grate).

Boiler principal human body will be loaded on the 20′ or 40′ FR(flat rack) containers with weather cloth,boiler components will be packed with plywood boxes and loaded in the twenty-toes or 40-feet GP(CZPT) containers.

Weclome to HangCZPT,we will discuss far more details,check our workshop and operating boilers.
 

Specs FOR DZL COAL FIRED STEAM BOILER

 

Boiler fundamental parameter

Steam ability

T/h

one, two,three,four, six, eight, 10, twelve, 15, twenty

Steam temperature

ºC

170, 184, 194, 204, 226

Gas

 

Coal,biomass

 

Boiler performance 

Operating force

Mpa

.7,1.,1.25, 2.,2.5

Thermal efficiency

%

eighty-85

Feed water temperature

ºC

twenty-one hundred and five

 

Boiler performance

Grate warmth region

1.5-23.fifteen

Gas intake

Kg/T(steam)

120

Max transportation bodyweight

T

sixteen-forty nine

 

Boiler design

Mal

 

DZL2-.7

/one.25/1.6-AII

DZL4-1.25

/1.six/2.five-AII

DZL6-one.25

/1.6/two.5-AII

DZL8-1.twenty five

/one.six/two.five-AII

DZL10-1.25

/one.6/two.5-AII

DZL20
-one.twenty five

/1.6/two.5-AII

Steam capability

T/h

         2

          4

          6

            8

          on

         20

Working force

Mpa

.7/1.twenty five/      1.6

one.25/one.6/        2.5

one.25/1.six/            2.5

one.25/one.6/             two.5

1.25/one.6/             2.five

1.twenty five/one.six/           two.5

Steam temp.

ºC

170/194/       204

194/206/       226

194/206/           226

194/206/           226

194/206/           226

194/206/             226

Feed drinking water temp.

ºC

        yirmi

         20

        20

        a hundred and five

        bir sıfır beş

       105

Thermal efficiency

%

        yetmiş sekiz

       78

         80

         80

         80

        eighty two

Grate heat region

       3.two

      five.fourteen

         7.four

         9.six

       11.four

     23.15

Coal CZPT

 

                              II variety bituminous, reduced heat capacity:17700-21000KJ/kg

 

Drinking water pump

Ürün

 

1½GC5×7

1½GC5×7

2GC-5×6

2½GC6×6

DG12×7

DG25
-35×5

Motor energy

Kw

   7.5/11

seven.five/11/          18.5

fifteen/18.5

fifteen/18.5

eighteen.5/22

thirty/37

 

 

 

 

Blast fan

Ürün

 

G6-forty one-13
NO5.4A

G6-forty one-thirteen
NO6.4A

G6-41-thirteen
NO7.1A

G6-41-13
NO8.5A

G6-41-13
NO8.5A

TG20-one

Ventilation

 

m³/h

4358-2310

7358-3596

1 0571 -5394

18137-9369

18137-9367

32079

Wind force

 

Pa

 

994-1254

1181-1436

 

1697-2270

 

2535-3391

 

2535-3391

 

2559

Motor electrical power

Kw

         3

      beş.beş

        yedi.beş

       18.5

       18.beş

        37

Induced draft fan

     Model

 

Y6-41-thirteen
NO5.4C

Y6-forty one-thirteen
NO7.1C

1Y6-41-thirteen
NO10C

Y6-forty one-thirteen
NO11.Second

Y6-41-thirteen
NO11.2nd

GY20-fifteen

Ventilation

m³/h

8901-4350

15219-8171

32144-16607

41773-21578

41773-21578

73308

Wind pressure

 

Pa

2568-3240

2454-3283

 

2574-3444

 

2764-3697

 

2764-3697

 

3515

Motor energy

Kw

      on bir

        22

         37

       45

        55

       110

Maximum size for cargo

M

five.82×2.1×3.two

six.5×2.sixty six
×3.fifty two

six.7×3
×3.fifty four

eight.0×3.two
×3.58

eight.45×3.two
×3.fifty eight

10×4.8
×3.fifty five

Optimum excess weight for cargo

T

eighteen/19/20

27/29/31

32/33/34

42/43/44

forty five/forty seven/forty nine

30/31/3

Sertifikalar

 

Special Design Begass Fired Steam Boiler

Etiketler: