Large Effectiveness 11KW 41000RPM Servo CZPT AC Motor
Solution Attribute
1.Ideal for the 7159rpm large velocity
2.Higher electricity & high torque
three.Substantial performance
4.Modest size
five.Lower noise lower vibration
six.Patented cooling framework
seven.Easy servicing and lengthy life time
8.Sturdy, dependable
Requirements
Design type: SRPM130
Voltage: 380V AC
Rated Electrical power: 11KW
Charge Torque : 2.56 N.m
Doing work speed: 41000rpm
Isolation: H
Cooling Method: Air
Pole: two
برمجة
Higher-velocity Compressors,Fans,Pumps
Other motors you will be intrigued in
| Motor type | الجهد االكهربى (V AC) |
Rated electricity (kW) |
Rated torque (N.m) | Rated velocity (rpm) |
أداء (%) |
Service Issue | Insulation | Ingress defense | Pole Number | وزن الجسم (kg) |
Cooling Strategy | Place Sign | Installation Approach |
| SRPM151M8XW11 | 380 | أحد عشر | 11 | 9600 | 96 | S1 | H/F | IP67 | 8 | 10 | Oil circulation | Resolver | B35 |
| SRPM205M8XO45 | 380 | خمسة وأربعون | 36 | 12000 | 96.3 | S1 | H/F | IP67 | 8 | 35 | Oil circulation | Resolver | B35 |
| SRPM205M8XO55 | 380 | خمسة وخمسون | forty three.8 | 12000 | ninety six.3 | S1 | H/F | IP67 | ثمانية | 38 | Oil circulation | Resolver | B35 |
| SRPM205M8XO75 | 380 | 75 | 59.7 | 12000 | ninety six.five | S1 | H/F | IP67 | 8 | forty three | Oil circulation | Resolver | B35 |
| SRPM205M8XO90 | 380 | ninety | 71.6 | 12000 | ninety six.5 | S1 | H/F | IP67 | ثمانية | forty seven | Oil circulation | Resolver | B35 |
| SRPM205M8XO110 | 380 | مائة وعشرة | 87.6 | 12000 | 96.five | S1 | H/F | IP67 | ثمانية | 75 | Oil circulation | Resolver | B35 |
| SRPM205M8XO132 | 380 | 132 | one hundred and five | 12000 | 96.five | S1 | H/F | IP67 | 8 | eighty | Oil circulation | Resolver | B35 |
| SRPM205M8XO160 | 380 | one hundred sixty | 127.three | 12000 | 96.5 | S1 | H/F | IP67 | ثمانية | 87 | Oil circulation | Resolver | B35 |
| SRPM205M8XO185 | 380 | 185 | 147.two | 12000 | ninety six.5 | S1 | H/F | IP67 | ثمانية | 95 | Oil circulation | Resolver | B35 |
التعليمات
1. Can performanent magnet synchronous motor be used as generator?
No. Long term magnet synchronous motor is definitely distinct from generator. It is only ac motor that outputs pace and torque to travel electric units, but not electricity offer.
2. Why can not straight use 3 section ac supply voltage to commence everlasting magnet synchronous motor?
Becuase rotor is with massive innertia, and magetic information spins so quickly that static rotor has no way to spin with magetic filed.
three. Any special technological ask for on this motor’s VFD driver? And Do you have such driver?
Long term magnet synchronous motor’s driver should be vector manage VFD with special interior software program, such as Siemens 6SE70 collection, Yakawa CR5 collection, ABB ACS800 sequence, Mitsubishi A740 collection, B&R P84 and P74 series, and so forth.. Indeed, our MH300 sequence VFD matches with this motor.
4. Is there any protecting measures to defend long term magnet rotor from failure?
Of course, every long lasting magnet rotor passes corrossion resistance, regularity, large temperature demagnetization check, linear demagnetization test, and so forth. Its demagnetization index is within two%. But if working environment is critical oxiditive corrosion, kindly advise for higher protection amount.
five. The place is this long term magnet synchronous motor normally employed to?
This permanent magnet synchronous motor is typically used to variable frequency speed scenario.