{"id":1888,"date":"2020-12-17T09:43:47","date_gmt":"2020-12-17T09:43:47","guid":{"rendered":"https:\/\/motorcyclechain.top\/ce-approved-yc-series-heavy-duty-single-phase-induction-motor\/"},"modified":"2020-12-17T09:43:47","modified_gmt":"2020-12-17T09:43:47","slug":"ce-approved-yc-series-heavy-duty-single-phase-induction-motor","status":"publish","type":"post","link":"https:\/\/motorcyclechain.top\/ja\/ce-approved-yc-series-heavy-duty-single-phase-induction-motor\/","title":{"rendered":"Ce Approved Yc Series Heavy-Duty Single-Phase Induction Motor"},"content":{"rendered":"<p><img decoding=\"async\" style=\"height:auto\" title=\"Ce Approved Yc Series Heavy-Duty Single-Phase Induction Motor\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/motor-base-1.jpg\" alt=\"Ce Approved Yc Series Heavy-Duty Single-Phase Induction Motor\" \/><\/p>\n<p>\n<p>\u00a0<br \/><strong>\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2<\/strong><\/p>\n<p>\u00a0 YC series\u00a0 motor is developed and manufacyured in accordance to national standard JB\/T 1011 it has the charscter istics of simple framework,trustworthy procedure, practical routine maintenance,sat is manufacturing unit technological and cost-effective efficiency,high commencing torque and sturdy in excess of load,potential which is extensively employed in air compressor,pump washing machine,fridge as properly as other machines.<\/p>\n<p><strong><strong>Working Situations:<\/strong><\/strong><\/p>\n<table>\n<tbody>\n<tr>\n<td>Ambient temperature<\/td>\n<td>-15\u00b0c to 40 \u00b0c<\/td>\n<\/tr>\n<tr>\n<td>\u9ad8\u5ea6<\/td>\n<td>\u22641000m<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u96fb\u5727<\/td>\n<td>one period: 110V, 115V, 120V, 220V, 230V, 240V, and so on<\/td>\n<\/tr>\n<tr>\n<td>\u5b9a\u683c\u5468\u6ce2\u6570<\/td>\n<td>50HZ, 60HZ, 50HZ\/60HZ<\/td>\n<\/tr>\n<tr>\n<td>Obligation<\/td>\n<td>Continuous(S1)<\/td>\n<\/tr>\n<tr>\n<td>Insulation class<\/td>\n<td>Course B, Class F. ClassH<\/td>\n<\/tr>\n<tr>\n<td>Protection class<\/td>\n<td>IP44, IP54,\u00a0<\/td>\n<\/tr>\n<tr>\n<td>Cooling strategy<\/td>\n<td>IC0141<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><p>\u00a0<\/p>\n<p><strong>CZPT Information:<\/strong><\/p>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td rowspan=\"2\">Sort<\/td>\n<td colspan=\"2\">\u51fa\u529b<\/td>\n<td rowspan=\"2\">\u65e2\u5b58<br \/>\uff08A\uff09<\/td>\n<td rowspan=\"2\">Electricity Issue<\/td>\n<td rowspan=\"2\">Eff<br \/>(%)<\/td>\n<td rowspan=\"2\">\u30b9\u30d4\u30fc\u30c9<br \/>(r\/min)<\/td>\n<td rowspan=\"2\">Tst\/Tn<\/td>\n<td rowspan=\"2\">Ist\/IN<\/td>\n<td rowspan=\"2\">Tmax\/Tn<\/td>\n<\/tr>\n<tr>\n<td>\u30ad\u30ed\u30ef\u30c3\u30c8<\/td>\n<td>HP<\/td>\n<\/tr>\n<tr>\n<td>YC80A-2<\/td>\n<td>.37<\/td>\n<td>one\/2<\/td>\n<td>3.7<\/td>\n<td>.seventy three<\/td>\n<td>62<\/td>\n<td>2880<\/td>\n<td>2.8<\/td>\n<td>6.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC80B-2<\/td>\n<td>.55<\/td>\n<td>3\/4<\/td>\n<td>5.3<\/td>\n<td>.73<\/td>\n<td>65<\/td>\n<td>2880<\/td>\n<td>2.8<\/td>\n<td>6.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC80C-2<\/td>\n<td>75<\/td>\n<td>1<\/td>\n<td>6.three<\/td>\n<td>.75<\/td>\n<td>68<\/td>\n<td>2880<\/td>\n<td>2.8<\/td>\n<td>6.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC90S-2<\/td>\n<td>1.1<\/td>\n<td>1.5<\/td>\n<td>nine.1<\/td>\n<td>.seventy nine<\/td>\n<td>71<\/td>\n<td>2880<\/td>\n<td>2.5<\/td>\n<td>7.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC90L-two<\/td>\n<td>1.5<\/td>\n<td>2<\/td>\n<td>12.1<\/td>\n<td>.84<\/td>\n<td>72<\/td>\n<td>2900<\/td>\n<td>2.5<\/td>\n<td>seven.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC100L-two<\/td>\n<td>2.2<\/td>\n<td>3<\/td>\n<td>17.one<\/td>\n<td>.84<\/td>\n<td>seventy four<\/td>\n<td>2900<\/td>\n<td>2.2<\/td>\n<td>7.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC112M1-two<\/td>\n<td>\u4e09\u3064<\/td>\n<td>4<\/td>\n<td>21.4<\/td>\n<td>.86<\/td>\n<td>76<\/td>\n<td>2900<\/td>\n<td>2.2<\/td>\n<td>seven.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC112M2-2<\/td>\n<td>three.7<\/td>\n<td>5<\/td>\n<td>24.eight<\/td>\n<td>.86<\/td>\n<td>seventy nine<\/td>\n<td>2900<\/td>\n<td>2.2<\/td>\n<td>7.<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC80A-4<\/td>\n<td>\u300225<\/td>\n<td>1\/3<\/td>\n<td>three.4<\/td>\n<td>.60<\/td>\n<td>56<\/td>\n<td>1450<\/td>\n<td>\u4e09\u3064\u3002<\/td>\n<td>6<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC80B-four<\/td>\n<td>.37<\/td>\n<td>one\/2<\/td>\n<td>4.5<\/td>\n<td>65<\/td>\n<td>60<\/td>\n<td>1450<\/td>\n<td>2.8<\/td>\n<td>\u516d<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC80C-four<\/td>\n<td>.55<\/td>\n<td>3\/4<\/td>\n<td>6.<\/td>\n<td>.66<\/td>\n<td>64<\/td>\n<td>1450<\/td>\n<td>2.8<\/td>\n<td>6.five<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC90S-four<\/td>\n<td>75<\/td>\n<td>1<\/td>\n<td>seven.<\/td>\n<td>.sixty eight<\/td>\n<td>67<\/td>\n<td>1450<\/td>\n<td>2.5<\/td>\n<td>six.five<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC90L-4<\/td>\n<td>1.1<\/td>\n<td>1.5<\/td>\n<td>10.5<\/td>\n<td>.sixty eight<\/td>\n<td>70<\/td>\n<td>1450<\/td>\n<td>2.5<\/td>\n<td>6.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC100L-four<\/td>\n<td>1.5<\/td>\n<td>2<\/td>\n<td>13.five<\/td>\n<td>.70<\/td>\n<td>72<\/td>\n<td>1450<\/td>\n<td>2.5<\/td>\n<td>six.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC112M-four<\/td>\n<td>2.2<\/td>\n<td>3<\/td>\n<td>19.three<\/td>\n<td>.72<\/td>\n<td>72<\/td>\n<td>1450<\/td>\n<td>2.2<\/td>\n<td>6.five<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC132S1-4<\/td>\n<td>\u4e09\u3064\u3002<\/td>\n<td>4<\/td>\n<td>25.two<\/td>\n<td>.73<\/td>\n<td>74<\/td>\n<td>1450<\/td>\n<td>2.one<\/td>\n<td>six.five<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC132S2-four<\/td>\n<td>three.seven<\/td>\n<td>5<\/td>\n<td>30<\/td>\n<td>.74<\/td>\n<td>75<\/td>\n<td>1450<\/td>\n<td>two.1<\/td>\n<td>six.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC132M1-4<\/td>\n<td>5.5<\/td>\n<td>7.5<\/td>\n<td>32.five<\/td>\n<td>.ninety five<\/td>\n<td>81<\/td>\n<td>1460<\/td>\n<td>two.one<\/td>\n<td>6.5<\/td>\n<td>1.8<\/td>\n<\/tr>\n<tr>\n<td>YC132M2-four<\/td>\n<td>7.5<\/td>\n<td>10<\/td>\n<td>40<\/td>\n<td>.ninety five<\/td>\n<td>82<\/td>\n<td>1460<\/td>\n<td>2.<\/td>\n<td>six.five<\/td>\n<td>1.8<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u00a0<\/p>\n<p><strong><\/strong><\/p>\n<p><em><strong>\u00a0 \u00a0<br \/>Why us?\u00a0<\/strong><\/em><\/p>\n<p>1.Reduced MOQ:\u00a0It can meet your promotional business quite well.<br \/>\u00a0\u00a0<br \/>2.Good Provider :\u00a0We deal with clientele as buddies,supplying 24 hrs a times 7days a 7 days support assistance.<\/p>\n<p>\u00a03.Good Good quality :We have rigid good quality control system.Excellent popularity in the market.<br \/>\u00a0<br \/>four.Fast &amp;\u00a0Cheap Shipping:\u00a0We have big low cost from CZPTer<\/p>\n<p><em><strong>\u3088\u304f\u3042\u308b\u8cea\u554f<\/strong><\/em><\/p>\n<p>Q: Do you provide OEM provider?<\/p>\n<p>A: Yes\u00a0<\/p>\n<p>Q: What is your payment phrase?<\/p>\n<p>A: 30% T\/T in advance, 70% balance when getting B\/L copy.\u00a0\u00a0Or irrevocable L\/C.<\/p>\n<p>Q: What is your lead time?<\/p>\n<p>A: About thirty days after obtaining deposit or original L\/C.<\/p>\n<p>\n<p><img decoding=\"async\" style=\"height:auto\" title=\"Ce Approved Yc Series Heavy-Duty Single-Phase Induction Motor\" src=\"http:\/\/img.hzpt.com\/uploads\/images\/ZHMedical\/motor-base-2.jpg\" alt=\"Ce Approved Yc Series Heavy-Duty Single-Phase Induction Motor\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>\u00a0Software \u00a0 YC series\u00a0 motor is developed and manufacyured in accordance to national standard JB\/T 1011 it has the charscter istics of simple framework,trustworthy procedure, practical routine maintenance,sat is manufacturing unit technological and cost-effective efficiency,high commencing torque and sturdy in excess of load,potential which is extensively employed in air compressor,pump washing machine,fridge as properly as other machines. Working Situations: Ambient temperature -15\u00b0c to 40 \u00b0c Altitude \u22641000m Rated voltage one period: 110V, 115V, 120V, 220V, 230V, 240V, and so on Rated frequency 50HZ, 60HZ, 50HZ\/60HZ Obligation Continuous(S1) Insulation class Course B, Class F. ClassH Protection class IP44, IP54,\u00a0 Cooling strategy IC0141 \u00a0 CZPT Information: Sort Output Existing(A) Electricity Issue Eff(%) [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-1888","post","type-post","status-publish","format-standard","hentry","category-product-catalog"],"_links":{"self":[{"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/posts\/1888","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/comments?post=1888"}],"version-history":[{"count":0,"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/posts\/1888\/revisions"}],"wp:attachment":[{"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/media?parent=1888"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/categories?post=1888"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/motorcyclechain.top\/ja\/wp-json\/wp\/v2\/tags?post=1888"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}